Purpose: Temperature measurement and sampling of metal melts
Application: Oxygen converters, electric arc furnaces, induction furnaces, and steel ladles
Measurement range:
from 1536 to 1800°C - metal temperature
Accuracy: ±0.0025T, °C
Shape of the sampled metal:
Circle: thickness of 12 mm
Oval: thickness 12 mm
Deoxidizer: No deoxidizer, aluminum, zirconium, titanium
Measurement time: 8 seconds
Tube length: 100 to 2500 mm (other lengths are available upon request)
Slag cap: Steel, aluminum, copper, cardboard
NSC type: B, S